- Water Temperature: Adjustment of maximum water temperature in the boiler.
- Flue Gas Temperature: Adjustment of maximum flue gas temperature (°C). When the flue gas temperature exceeds this value, the boiler automatically switches to reduced combustion mode.
- Circulator Temperature: Starting temperature of the circulator.
- Bypass Temperature: Adjustment of water temperature in the boiler above which the <<BYPASS>> outlet is activated for the operation of the electric valve of the expansion tank or for circuit cooling (open circuit).
- Combustion Air: Adjustment of the intensity (%) of the fan during the full combustion process.
- Water Temperature DT: Differential water temperature of the boiler for activating the economy automation. (the air gradually decreases as the maximum water temperature approaches)
- Flue Gas Temperature DT: Differential flue gas temperature of the boiler for activating the economy automation. (the air gradually decreases as the maximum flue gas temperature approaches)
- Combustion Air Supply: Adjustment of the air supply required for ignition and flame stabilization during the ignition process.
- Max Time: The maximum time for the "automatic ignition" process to be completed.
- Flue Gas Off Time: Time during which the flue gas temperature must be below the set limit in order to consider the wood fuel operation finished.
- Flue Gas Temperature Off: Flue gas temperature below which the fuel is considered finished.
- Maintenance Time: Adjustment of the time interval for the operation of the <<combustion maintenance>>.
- Maintenance Duration: Adjustment of the duration of the <<combustion maintenance>> operation.
- Air Motor Type: Selection of the air motor type. If the "NORMAL" setting does not sufficiently reduce the revolutions at the desired point, select "HIGH TORQUE".